Expand | ||||||
---|---|---|---|---|---|---|
| ||||||
|
Expand | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||
|
Expand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
HaftungLiability
Garantie
Software
Datenlogger, Sensoren und Zubehör
Markenzeichen
Note |
Warranty
Software
Data loggers, sensors and accessories
Trademark
|
Expand | ||
---|---|---|
| ||
|
1.
ÜbersichtOverview Monitor
Diese Anwendung wird für die Überwachung, die Anzeige und die Archivierung der Sensordaten der This application is used for monitoring, displaying and archiving the sensor data of the I/O Module modules (ECOLOG-PRO, ECOLOG-NET) sowie zur Weiterleitung von Alarmmeldungen verwendetand for forwarding alarm messages.
1.1.
BenutzeroberflächeNach dem erfolgreichen Anmelden wechselt elproMONITOR in das in 4 Bereiche aufgeteilte StartfensterUser Interface
After the successful login, elproMONITOR changes to the start window divided into 4 areas.
Drawio | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Anchor | ||||
---|---|---|---|---|
|
|
The priority defines which sensor status is displayed if a sensor has several statuses at the same time. The status with the highest priority is displayed in each case.
Status LED | Status | PrioritätPriority | BeschreibungDescription | ||||
---|---|---|---|---|---|---|---|
OK | 1 | Alles All in Ordnungorder. | |||||
Schwache Funkstärke | 2 | Die Funkstärke des entsprechenden Moduls ist zu schwach. Der Status wird sofort angezeigt, wenn ein Alarmprofil mit entsprechendem Sensoralarm eingestellt wurde. Der Alarm wird aber erst nach Ablauf der Verzögerungszeit ausgelöst. | |||||
Tiefer Batteriestand | 3 | Die Sensorspeisung hat einen tiefen Batteriestand. | |||||
Warnung untere Grenze | 4 | Der Messwert ist tiefer als die obere Warngrenze. | |||||
Warnung obere Grenze | 5 | Der Messwert ist höher als die obere Warngrenze. | |||||
Warnung digitaler Eingang | 6 | Der Zustand des digitalen Eingangs entspricht dem Alarmkriterium. | |||||
Alarm untere Grenze | 7 | Der Messwert ist tiefer als die obere Alarmgrenze. | |||||
Alarm obere Grenze | 8 | Der Messwert ist höher als die obere Alarmgrenze. | |||||
Logger Intervall Fehler | 9 | ECOLOG-NET - Falsches Aufzeichnungsintervall für das Nachladen parametriert. | |||||
Sensorstörung | 10 | Der Sensor ist ausgefallen. | |||||
keine Verbindung | 11 | elproMONITOR hat keine Verbindung zum Modul / Datenlogger, an dem der betroffene Sensor angeschlossen ist. | |||||
Nachladen | 12 | Nach einem Verbindungsunterbruch werden im Modul gepufferte Werte nachgeladen.
| |||||
Deaktiviert durch Benutzer | 13 | Der Sensoralarm wurde durch den Kalibrierungsprozess deaktiviert. | |||||
Deaktiviert durch Zeitsteuerung | 14 | Der Sensoralarm wurde von der Zeitsteuerung deaktiviert. | |||||
Deaktiviert durch Kalibrierung | 15 | Der Sensoralarm wurde vom Benutzer deaktiviert. | |||||
Stillgelegt | 16 | Der Sensor wird nicht weiter überwacht und kann nicht wieder aktiviert werden. Die aufgezeichneten Messwerte werden nicht gelöscht und können nachwie vor über die Sensoranalyse abgerufen werden. Info | | Weak radio strength | 2 | The radio strength of the corresponding module is too weak. The status is displayed immediately if an alarm profile with corresponding sensor alarm has been set. However, the alarm is only triggered after the delay time has elapsed. | |
Low battery level | 3 | The sensor supply has a low battery level. | |||||
Warning lower limit | 4 | The measured value is lower than the upper warning limit. | |||||
Warning upper limit | 5 | The measured value is higher than the upper warning limit. | |||||
Warning digital input | 6 | The state of the digital input corresponds to the alarm criterion. | |||||
Alarm lower limit | 7 | The measured value is lower than the upper alarm limit. | |||||
Alarm upper limit | 8 | The measured value is higher than the upper alarm limit. | |||||
Logger interval error | 9 | ECOLOG-NET - Incorrect recording interval parameterized for reloading. | |||||
Sensor malfunction | 10 | The sensor has failed. | |||||
No connection | 11 | elproMONITOR has no connection to the module / data logger to which the affected sensor is connected. | |||||
Reload | 12 | After a connection interruption, buffered values are reloaded in the module.
| |||||
Deactivated by user | 13 | The sensor alarm was deactivated by the calibration process. | |||||
Deactivated by time control | 14 | The sensor alarm has been deactivated by the time control. | |||||
Deactivated by calibration | 15 | The sensor alarm has been deactivated by the user. | |||||
Retired | 16 | The sensor is no longer monitored and cannot be reactivated. The recorded measured values are not deleted and can still be called up via the sensor analysis.
|
Anchor | ||||
---|---|---|---|---|
|
Sensor Analysis
elproMONITOR has several functions for analyzing and exporting the recorded measured values.
Drawio | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
1.3.1
. Zeitraum für Sensoranalyse auswählenSelect Period for Sensor Analysis
1.3.2
. Anwendbare FunktionenApplicable Functions
Anchor | ||||
---|---|---|---|---|
|
Details
SensoranalyseSensor Analysis
1.3.4. Messwerte nachladen
Nach einem Systemausfall lädt elproMONITOR die fehlenden Messwerte aus dem internen Speicher der Datenlogger nach. Durch dieses Verfahren werden fehlende Daten automatisch nachgeführt und vorhandene Aufzeichnungslücken geschlossen1.3.4 Reload measured values
After a system failure, elproMONITOR reloads the missing measured values from the internal memory of the data loggers. This procedure automatically replenishes missing data and closes existing recording gaps.
Note |
---|
ECOLOG-PROBeim In ECOLOG-PRO ist die Funktion Nachladen unabhängig vom Aufzeichnungsintervall der einzelnen Module, the Reload function is independent of the recording interval of the individual modules. |
Note |
---|
ECOLOG-NETJeder Each ECOLOG-NET Logger muss auf einen Aufzeichnungsintervall von 1 Minute programmiert sein. Der Typischen Zeiträume für das Nachladen sind 5 Tage (8-Kanal Logger) oder 11 Tage (4-Kanal Logger)logger must be programmed for a recording interval of 1 minute. The typical time periods for reloading are 5 days (8-channel logger) or 11 days (4-channel logger). |
Info |
---|
ECOLOG-PRO RadioDie Nachladegeschwindigkeit bei den The reload speed of the ECOLOG-PRO Radio Modulen wird begrenzt durch die Funkübertragung. Es können 114 Messwerte pro Minute und Kanal übertragen werden. Zum Beispiel benötigt ein ECOLOG-PRO 1NTR Messmodul ca. 130 Minuten um einen komplett vollen Puffer nachzuladen. Die ECOLOG-PRO Radio Module radio modules is limited by the radio transmission. 114 measured values per minute and channel can be transmitted. For example, an ECOLOG-PRO 1NTR measuring module requires approx. 130 minutes to reload a completely full buffer. The ECOLOG-PRO radio modules ECOLOG-PRO 1NTR, 2PTR und 1THR können unter optimalen Bedingungen 114 Messwerte pro Minute und Kanal nachladen. Bei grösseren Systemen kann sich die Nachladezeit ebenfalls vergrössern. |
and 1THR can reload 114 measured values per minute and channel under optimal conditions. With larger systems, the reload time may also increase. |
The current connection status of the module is indicated by the following statuses (see >> 1.2. Statusstatus):
OK
keine Verbindung - Systemausfall oder Verbindungsunterbruch
Logger Intervall Fehler- Fehlermeldung: Logger Intervall Error, für einen ECOLOG-NET Logger bei falschem Aufzeichnungsintervall. Es werden keine Daten nachgeladen!
Nachladen - Nach einem Verbindungsunterbruch werden im Modul gepufferte Werte nachgeladen.
no connection - system failure or connection interruption
Logger Interval Error- Error message: Logger Interval Error, for an ECOLOG-NET logger with wrong logging interval. No data is reloaded!
Reload - After a connection interruption, buffered values are reloaded in the module.
Reloaded values are highlighted in the sensor analysis. See >> 1.3.3. Details Sensoranalysedetails sensor analysis
Page Tree | ||||
---|---|---|---|---|
|
Live Search |
---|