System Description elproMONITOR, ECOLOG-PRO and ECOLOG-NET
1. Introduction to elproMONITOR
This application is used for monitoring, displaying and archiving the sensor data of the I/O modules (ECOLOG-PRO, ECOLOG-NET) and for forwarding alarm messages.
The following functions are part of the elproMONITOR application:
Configuration
Calibration
Monitor sensors and record measured values
Alarm monitoring
Audit Trail
Together with elproMONITOR the following software packages are used:
elproEVENT - records all actions that occur at runtime of elproMONITOR
>> SV3031E elproEVENT operating instructionselproUSER - Program for user administration
>> SU3031E elproUSER operating instructions
The following module series with network connection (Ethernet) can be used with elproMONITOR:
1.1 Starting elproMONITOR
1.1.2 Log in
Starting the software
Enter username
Enter password
Click "LOGIN" button
Database settings
Session Time
Time period after the last action of the user, until the automatic logout from elproMONITOR.
1.1.3 User Interface
After the successful login, elproMONITOR changes to the start window divided into 4 areas.
I - Menu bar
Click on the ELPRO logo to open the elproMONITOR info window... with the current product version and program version.
Clicking on "Monitor" opens the start window or also >> elproMONITOR / Monitor
Clicking on "Calibration" opens >> elproMONITOR / Calibration
Clicking on "Deviations" opens >> elproMONITOR / Deviations
Clicking on "Settings" opens >> elproMONITOR / Settings
Click on "User" to go to the application >> elproUSER (operating instructions SU3031D) changed
Click on "Base" to start the ECOLOG-PRO Base Maintenance application. (>> Operating instructions EP6002D)
The following information is displayed right-aligned in the menu bar:
Load..: Reference to a loading process (e.g. when updating the measured values).
Currently set time zone (UTC +/- hh:mm)
Logout from elproMONITOR by clicking on Logout (Manadant/user)
Currently logged in client/user (optional, e.g. DevMonitor/admin) or user (e.g. admin) is displayed.
II - Overview column for groups, filters and settings
Here, depending on the selected overview, the following functionalities are displayed:
"Monitor": Selection option for all sensors and the sensor groups defined under Settings → Sensor groups.
"Calibration": Filter for active and all calibrations, filter by date and filter by calibration number
"Deviations": Filter for Active or Unacknowledged Deviations, Filter by Date, Filter by Incident Number, Filter by Sensor Alarms, Sensor Warnings, Sensor Malfunctions and System Malfunctions.
"Settings" Selection option for setting to devices, profiles, the program and the user.
III - Detail column
This area contains all information about the groups, filters or settings selected in the overview column.
The detail column consists of a column title (group 1) and the column content adapted to the selected overview (e.g. sensor, I/O module, alarm profile, value, status, etc.) as a table.
The following functionalities can be executed in the table:
A. Selection of all rows of the table for the execution of applicable functions (see IV).
B. Selection of single or several specific lines on which applicable functions (see IV) can be executed.
C. Sorting the column in ascending or descending order. The sorting process is triggered by a mouse click on the column title.
D. Functions that are executed directly on the corresponding line regardless of the line selection (see A or B).
IV - Applicable functions
Depending on the selected overview, different functionalities can be executed here.