- Created by Lango: Language and translation manager , last modified on Nov 20, 2023
- Translations
You are viewing an old version of this page. View the current version.
Compare with Current View Page History
« Previous Version 2 Next »
Information
Important information and warnings
DELETE | Windows function, e.g. Delete |
<xxxxxxxx> | Syntax for placeholders. |
>> | Reference to a further chapter or document. |
The illustration only refers to a part of the user interface. |
In the interest of our customers, we reserve the right to make changes due to technical progress. Schematics, descriptions and scope of delivery may therefore be changed without prior notice. This manual is valid from version 2017.
Liability
In no event shall ELPRO-BUCHS AG be liable for any direct, indirect, special, incidental, consequential or punitive damages or losses, including lost profits and data, arising out of the use of your data loggers, sensors, accessories, software products or the information contained in the documentation.
ELPRO-BUCHS AG is not responsible for the installation of the software products.
ELPRO-BUCHS AG makes no warranties, express or implied, as to the merchantability and fitness for a particular purpose of its products.
In the interest of our customers, we reserve the right to make changes and discontinuations due to technical progress. For this reason, functionality, schematics, descriptions and scope of delivery may be changed without prior notice!
Because some countries or states do not allow the limitation of the term of an implied warranty or disclaimer of incidental or consequential damages, the limitations and exclusions may not apply to every buyer. If any provision of this warranty is held by a court of competent jurisdiction to be invalid or unenforceable, the validity or enforceability of the remaining provisions shall not be affected.
ELPRO-BUCHS AG accepts no liability for transport damage or any consequential damage.
In general, the legal provisions of Switzerland apply. The place of jurisdiction is the district court of Werdenberg-Sarganserland.
Guarantee
The warranty obligations are limited, at the discretion of ELPRO-BUCHS AG, to rectification, refund of the purchase price, free repair or replacement of a defective product that has been returned to ELPRO-BUCHS AG or a reseller authorized by ELPRO-BUCHS AG within the warranty period.
There is no entitlement to free "on-site customer support" by an employee of ELPRO-BUCHS AG.
The warranty extends only to the original purchaser or end user and customers of a reseller authorized by ELPRO-BUCHS AG.
Resellers authorized by ELPRO-BUCHS AG are not entitled to provide a greater or other guarantee on behalf of ELPRO-BUCHS AG.
ELPRO-BUCHS AG grants a warranty period of 24 months on the following new products:
Data logger
Brackets
Accessories, excluding sensors and third-party products
This guarantee applies to material defects or production faults.
ELPRO-BUCHS AG grants a warranty period of 6 months for the following products and services:
All service work and repairs
Temperature sensors
Humidity sensors
ELPRO-BUCHS AG grants a warranty period of 90 days that the medium on which the software product was delivered is free from defects in material and workmanship under normal conditions. The software product complies in all material respects with the operating instructions and the information in the help file.
The warranty does not apply to consumables, disposable batteries or any other product which, in the opinion of ELPRO-BUCHS AG:
abused
changed
replaced by an incorrect product
has been operated and damaged outside the specification due to accident or operating or handling conditions.
Wear and tear, cable breakage and corrosion cannot be claimed under warranty.
For third-party products, ELPRO-BUCHS AG grants a maximum of the manufacturer's warranty period.
ELPRO-BUCHS AG only provides warranty work and customer support for discontinued products for a limited period of time.
Warranty repairs are only carried out at the factory (ELPRO-BUCHS AG) or at an agency recognized by the factory.
ELPRO-BUCHS AG does not guarantee the standard or SCS calibration of the data loggers and sensors. The specified data correspond to the situation during the calibration process
Software
The software products of ELPRO-BUCHS AG are subject to internal quality regulations and are regularly validated in the factory. In the event of any program errors, a workaround of the error is deemed to be rectification.
Software operating instructions do not contain instructions on the basic operation of a computer or the basic functions of the Windows® operating system. For information on operating your computer or operating system, please refer to the relevant manuals for your computer.
Data loggers, sensors and accessories
ELPRO-BUCHS AG applies the highest quality standards and ISO 9001 certified quality management in the manufacture of data loggers and their accessories.
For information on operating the data loggers and their accessories, please refer to the relevant product documentation provided by ELPRO-BUCHS AG.
The locally applicable installation regulations must be observed when installing data loggers, sensors and accessories.
For applications in potentially explosive atmospheres, the zone allocation specified by ELPRO-BUCHS AG and the application and safety instructions must be observed.
In the event of a warranty claim, the customer will receive a repair cost estimate from ELPRO-BUCHS AG in order to issue a corresponding authorization before work begins.
The transportation costs for a repair at ELPRO-BUCHS AG are borne by the customer. DAP (value added tax) is borne by ELPRO-BUCHS AG.
ELPRO-BUCHS AG reserves the right to charge the buyer for repair/part replacement costs.
After repair, the product will be returned to the buyer, with return shipping costs charged to the buyer (FOB shipping location).
Trademark
All listed company and product names and their trademarks are the protected property of their respective owners
CHANGES OR MODIFICATIONS TO THIS PRODUCT WILL VOID THE ETSI / FCC AUTHORIZATION TO OPERATE THIS PRODUCT. THIS PRODUCT COMPLIES WITH PART 15 OF THE FCC REGULATIONS AND RSS-210 INDUSTRY CANADA. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS PRODUCT MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS PRODUCT MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
| |
| |
|
1.1 Measuring module contact inputs - ECOLOG-PRO 4DO
ECOLOG-PRO 4DO, art. no. 801422
Module
Contact outputs for alarm forwarding
The contact outputs are designed as changeover switches (no / nc)
ID number
The ID number is used to identify the module in elproMONITOR.
Status indicator 1; module activity
green; power supply ok
blue; system bus activity
Status indicator 2; sensor status
Condition | Description |
---|---|
dark | No contact configured |
green | All configured contacts ok |
red | Failure of the external power supply to the alarm indicator. |
The display for the sensor status is updated at the recording interval!
System bus
Power supply for the connected measuring modules
Communication with the connected measuring modules
Connecting hook
For a secure connection between the modules, they are fixed at the back with the connecting hook.
1.1 Device data
Feeding
Through internal system bus
Contact output
The contact output is an electronic semiconductor contact
Only use for direct voltage (DCV)
Power supply for the alarm indicator
Terminal 5 of all 4 contacts is connected internally
Mass of the alarm indicator
Terminal 1 and terminal 3 of all 4 contacts are connected internally
The earth of the alarm indicator is electrically isolated from the earth of the system bus
External power supply unit for the alarm indicators
12 VDC..24 VDC
Switching current per contact
max. 100 mA
Connection cable lengths
max. 200m
Limit values & time behavior
The contacts are parameterized (limit values and alarm delay times) using elproMONITOR.
Date and time
Internal system clock
The internal system clock is permanently synchronized with the elproMONITOR system time
Scope of delivery
Module
Connecting hooks, see back of module
Info sheet
The plug connectors for the sensor connection are not included in the scope of delivery.
1.2 Contact states
The power supply unit must be connected for alarm signaling
Clamp | Occupancy |
---|---|
1 | GND Contact |
2 | NC (Normally Closed) Contact |
3 | GND Contact |
4 | NO (Normally Open) Contact |
5 | Contact for external power supply |
System start CH 1 - CH4
In this operating state, the normally closed contact and the normally open contact are open. There is no alarm signaling.
Module without power supply CH 2, 3, 4
In this operating state, the normally closed contact and the normally open contact are open. There is no alarm signaling.
Normal operation - no alarm CH 1 - 4
There is no alarm in this operating state.
Normal operation - Alarm CH 1 - 4
An alarm is present in this operating state
System alarm - Module without power supply - Watchdog CH 1
Channel 1 is in the alarm position for:
Failure of the module power supply
Interruption of the connection with the elproMONITOR software These two monitoring functions cannot be deactivated
Configured as an alarm contact in the elproMONITOR software
1.3 Wiring diagram - Local alarm
An alarm is triggered when the contact closes
2 local alarm indicators on contact CH1 and CH3
Clamp | Occupancy |
---|---|
1 | Mass |
2 | - |
3 | Mass |
4 | Closes on alarm / NO |
5 | Power supply for the alarm indicator Only one power supply unit is possible for all alarm outputs! |
1.4 Wiring diagram - alarm forwarding
An alarm is triggered when the contact opens. Wire break monitoring is possible with this connection diagram.
Contact CH1 monitored by building management system
Clamp | Occupancy |
---|---|
1 | Mass |
2 | Opens on alarm / NC |
3 | - |
4 | - |
5 | Power supply from alarm center |
- No labels