elproMONITOR / Deviations (EN)
1. Overview Deviations
The registered limit value violations and alarm messages are documented and acknowledged in the DEVIATIONS. The used limit values and alarm conditions are defined in the settings (see >> elproMONITOR / Settings). Alarms are forwarded by:
SMS
E-mail
ECOLOG-PRO 4DO (see >> Measuring module contact outputs - ECOLOG-PRO 4DO)
Alarm Interface LAN
1.1. User Interface
The Deviations overview is opened by clicking on the menu item "Deviations". The default view is deviations that are "Active or Unacknowledged".
A - Sensor Analysis
Left-clicking on a particular line opens the detailed view of this deviation. >> 1.2. deviations
I - Filter
The criteria listed in this column are used to filter the listed calibrations. The following criteria can be selected:
Filter
all deviations - all recorded error messages are listed.
Active or Unacknowledged - Only active or unacknowledged error messages are listed.
The handling of the error message is defined in the elproMONITOR database. A distinction is made between warnings and alarms. If "MustConfirmAlarms" is activated, an acknowledgement of the error message by the user is required. The acknowledgement of an error message is logged with date, time and user.
The following conditions are documented in the incident list:
Alarm status | Acknowledged | "MustConfirmAlarms" activated | "MustConfirmAlarms" not activated |
Active | Pending | The error message is listed in the incident list | |
Inactive | The error message is listed in the incident list | The error message is not listed | |
Active | Date/Time/User | The error message is listed in the incident list | |
Inactive | The error message is not listed | The error message is not listed | |
Occurred | Pending | The error message is listed in the incident list | |
Occurred | Date/Time/User | The error message is not listed | The error message is not listed |
Date filter
The period of the listed calibrations is limited to the specifications of start and to stop time.
Search
Search for a single calibration by specifying the number of the calibration.
Include
Selecting one of these filters inserts only the error messages belonging to the following filters into the incident list:
Sensor alarm - e.g. upper limit, lower limit, digital input alarm
Sensor warning - e.g. upper warning, lower warning
Sensor malfunction - e.g. no connection, sensor malfunction, low battery level
System error - e.g. Critical Device Error, Internal Error (program error with error message)
The "Filter" button is only active after entering the respective data. The filters cannot be combined with each other.
II - Detail column
This area contains the following information about the deviations in the incident list:
Incident No. - Consecutive incident number. Each error message is assigned a unique number.
Date - date and time of the error message.
Event - classification of the error message. >> elproMONITOR / Monitor / Status
Sensor - name of the sensor >> elproMONITOR / Settings / Device settings
I/O module - name of the I/O module >> elproMONITOR / Settings / Device settings
Alarm status
Acknowledged
The times for the date correspond to the selected UTC+/-hh:mm time zone of the user.
Detail
Switch to the detailed view for individual selected deviations. >> 1.2. details deviations